Solutions Category: Electronics & Accessories

Continuous ultraviolet to blue-green astrocomb

Yuk Shan Cheng, Kamalesh Dadi, Toby Mitchell, Samantha Thompson, Nikolai Piskunov, Lewis D. Wright, Corin B. E. Gawith,Richard A. McCracken & Derryck T. Reid

Abstract

Cosmological and exoplanetary science using transformative telescopes like the ELT will demand precise calibration of astrophysical spectrographs in the blue-green, where stellar absorption lines are most abundant. Astrocombs— lasers providing a broadband sequence of regularly-spaced optical frequencies on a multi-GHz grid—promise an atomically-traceable calibration scale, but their realization in the blue-green is challenging for current infrared laser-based technology. Here, we introduce a concept achieving a broad, continuous spectrum by combining second-harmonic generation and sum frequency-mixing in an MgO:PPLN waveguide to generate 390–520 nm light from a 1 GHz Ti:sapphire frequency comb. Using a Fabry-Pérot filter, we extract a 30 GHz sub-comb spanning 392–472 nm, visualizing its thousands of modes on a high-resolution spectrograph. Experimental data and simulations demonstrate how the approach can bridge the spectral gap present in second harmonic-only conversion. Requiring only ≈100 pJ pulses, our concept establishes a new route to broadband UV-visible generation at GHz repetition rates.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Practical quantum imaging with undetected photons

Emma Pearce, Nathan R. Gemmell, Jefferson Flórez, Jiaye Ding, Rupert F. Oulton, Alex S. Clark, and Chris C. Phillips

Abstract

Infrared (IR) imaging is invaluable across many scientific disciplines, from material analysis to diagnostic medicine. However, applications are often limited by detector cost, resolution and sensitivity, noise caused by the thermal IR background, and the cost, portability and tunability of infrared sources. Here, we describe a compact, portable, and low-cost system that is able to image objects at IR wavelengths without an IR source or IR detector. This imaging with undetected photons (IUP) approach uses quantum interference and correlations between entangled photon pairs to transfer image information from the IR to a wavelength which can be detected with a standard silicon camera. We also demonstrate a rapid analysis approach to acquire both phase and transmission image information. These developments provide an important step towards making IUP a commercially viable technique.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Bond-Selective Imaging of Cells by Mid-Infrared Photothermal Microscopy in High Wavenumber Region

Yeran Bai, Delong Zhang and Chen Li

Abstract

Using a visible beam to probe the thermal effect induced by infrared absorption, mid-infrared photothermal (MIP) microscopy allows bond-selective chemical imaging at submicron spatial resolution. Current MIP microscopes cannot reach the high wavenumber region due to the limited tunability of the existing quantum cascade laser source. We extend the spectral range of MIP microscopy by difference frequency generation (DFG) from two chirped femtosecond pulses. Flexible wavelength tuning in both C-D and C-H regions was achieved with mid-infrared power up to 22.1 mW and spectral width of 29.3 cm⁻¹. Distribution of fatty acids in live human lung cancer cells was revealed by MIP imaging of the C-D bond at 2192 cm⁻¹.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Compact and versatile OPG-OPA based on a periodically poled nonlinear crystal pumped by femtosecond Ytterbium fiber laser

Valerian Freysza , Gabriel Amiard-Hudebinea , Yoann Zaouterb , and Eric Freysza

Abstract

A 10 mm long PPLN crystal pumped by 125 nJ, 250 fs pulses centered at 1035 nm yielded by Yb3+ femtosecond fiber oscillator generates femtosecond signal and idler pulses tunable in the 1.35 µm – 1.65 µm and 2.6 µm – 4.2 µm spectral ranges. A numerical model accounting for both second- and third-order nonlinear processes well agree with the recorded signal conversion efficiency (up to 42%), the spectral and temporal profile of the generated pulses. Pulse to pulse stability is drastically improved injecting this compact and versatile device with a continuum generated in a photonic fiber. Further improvements are discussed.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Isotope ratio dual-comb spectrometer

Alexandre Parriaux, Kamal Hammani, Christophe Thomazo, Olivier Musset, and Guy Millot

Abstract

We demonstrate the use of dual-comb spectroscopy for isotope ratio measurements. We show that the analysis spectral range of a free-running near-infrared dual-comb spectrometer can be extended to the midinfrared by difference frequency generation to target specific spectral regions suitable for such measurements and especially the relative isotopic ratio δ13C. The measurements performed present very good repeatability over several days with a standard deviation below 2‰ for a recording time of a few tens of seconds, and the results are compatible with measurements obtained using an isotope ratio mass spectrometer. Our setup also shows the possibility to target several chemical species without any major modification, which can be used to measure other isotopic ratios. Further improvements could decrease the uncertainties of the measurements, and the spectrometer could thus compete with isotope ratio spectrometers currently available on the market.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Spatial Properties of Entangled Two-Photon Absorption

D. Tabakaev, A. Djorović, L. La Volpe, G. Gaulier, S. Ghosh, L. Bonacina, J.-P. Wolf, H. Zbinden, and R. T. Thew

Abstract

We experimentally study entangled two-photon absorption in rhodamine 6G as a function of the spatial properties of a high flux of broadband entangled photon pairs. We first demonstrate a key signature dependence of the entangled two-photon absorption rate on the type of entangled pair flux attenuation: linear, when the laser pump power is attenuated, and quadratic, when the pair flux itself experiences linear loss. We then perform a fluorescence-based Z-scan measurement to study the influence of beam waist size on the entangled two-photon absorption process and compare this to classical single- and two-photon absorption processes. We demonstrate that the entangled two-photon absorption shares a beam waist dependence similar to that of classical two-photon absorption. This result presents an additional argument for the wide range of contrasting values of quoted entangled two-photon absorption cross sections of dyes in literature.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Compact picosecond mid-IR PPLN OPO with controllable peak powers

Yudi Wu, Sijing Liang, Qiang Fu, Lin Xu, and David J. Richardson

Abstract

We report a high-repetition-rate, compact, mid-infrared picosecond (ps) optical parametric oscillator (OPO) based on periodically poled lithium niobate (PPLN). The OPO is synchronously pumped by an ytterbium-doped-fibre (YDF) master-oscillator-power-amplifier (MOPA) system, seeded by a 1040-nm gain-switched laser diode (GSLD). Under continuous-wave (cw) pulsed operation, at a 1.5-GHz repetition rate and 14-Wpump power, an idler average power of 2.4 W (30 W peak power) was achieved, with an idler wavelength tunability of 2260–3573 nm. Through the addition of an electro-optic modulator (EOM) to the MOPA system, acting as a time gate to suppress a variable number of pulses per 1 μs, a quasi-cw pumping regime was realized, allowing burst-mode operation of the OPO at a 1-MHz inter-burst repetition rate. By varying the burst window time with the EOM, controllable idler peak powers of up to 1.2 kW were then realized.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Quasi-CW Pumping of a Single-Frequency Fiber Amplifier for Efficient SHG in PPLN Crystals with Reduced Thermal Load

Enkeleda Balliu ,Magnus Engholm, Michel J. F. Digonnet and Hans-Erik Nilsson

Abstract

Single-frequency lasers are essential for high-resolution spectroscopy and sensing applications as they combine high-frequency stability with low noise and high output power stability. For many of these applications, there is increasing interest in power-scaling single-frequency sources, both in the near-infrared and visible spectral range. We report the second-harmonic generation of 670 µJ at 532 nm of a single-frequency fiber amplifier signal operating in the quasi-continuous-wave mode in a 10-mm periodically poled Mg-doped lithium niobate (MgO:PPLN) crystal, while increasing compactness. To the best of our knowledge, this is the highest pulse energy generated in this crystal, which may find applications in the visible and UV such as remote Raman spectroscopy.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Mid-infrared coincidence measurements on twin photons at room temperature

M. Mancinelli, A. Trenti, S. Piccione, G. Fontana, J.S. Dam, P. Tidemand-Lichtenberg, C. Pedersen & L. Pavesi

Abstract

Quantum measurements using single-photon detectors are opening interesting new perspectives in diverse fields such as remote sensing, quantum cryptography and quantum computing. A particularly demanding class of applications relies on the simultaneous detection of correlated single photons. In the visible and near infrared wavelength ranges suitable single-photon detectors do exist. However, low detector quantum efficiency or excessive noise has hampered their mid-infrared (MIR) counterpart. Fast and highly efficient single-photon detectors are thus highly sought after for MIR applications. Here we pave the way to quantum measurements in the MIR by the demonstration of a room temperature coincidence measurement with non-degenerate twin photons at about 3.1 mm. The experiment is based on the spectral translation of MIR radiation into the visible region, by means of efficient up-converter modules. The up-converted pairs are then detected with low-noise silicon avalanche photodiodes without the need for cryogenic cooling.

Read paper in full

Share article

  • Twitter
  • LinkedIn

Picosecond Pulsed Squeezing in Thin-Film Lithium Niobate Strip-Loaded Waveguides at Telecommunication Wavelengths

Daniel Peace, Alexander Zappacosta, Robert Cernansky, Ben Haylock, Andreas Boes, Arnan Mitchell, Mirko Lobino

Abstract

Achieving high level of pulsed squeezing, in a platform which offers integration and stability, is a key requirement for continuous-variable quantum information processing. Typically highly squeezed states are achieved with narrow band optical cavities and bulk crystals, limiting scalability. Using single-pass parametric down conversion in an integrated optical device, we demonstrate quadrature squeezing of picosecond pulses in a thin-film lithium niobate strip-loaded waveguide. For on-chip peak powers of less than 0.3 W, we measure up to -0.33±0.07 dB of squeezing with an inferred on-chip value of -1.7±0.4 dB. This work highlights the potential of the strip-loaded waveguide platform for broadband squeezing applications and the development of photonic quantum technologies.

Read paper in full

Share article

  • Twitter
  • LinkedIn